20.
Connect hose (17) to cooling package assembly and tighten clamp (16).
21.
Connect hose (15) to cooling package assembly and tighten clamp (14).
N OT E
Tighten tiedown strap installed in step 13 after performing step 22.
22.
Insert hose (11) through retaining clip (13) and connect to radiator filler cap (12).
23.
Install T (8) on radiator top tank (10).
24.
Install new O-ring (9) and connect hose (7) to T (8). Tighten clamp (6).
25.
Install new O-ring (5) and connect hose (2) to T (8). Tighten clamp (4).
26.
Install T (3) on cooling package.
27.
Connect hose (2) to T (3) and tighten clamp (1).
427-C0386
28.
Fill cooling system (WP 0041 00).