PANEL BOX CIRCUIT BREAKER INSTALLATION
INSTRUMENT CLUSTER REPLACEMENT

Field Maintenance Manual 2 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  38    39    40    41    42  43  44    45    46    47    48  
img
TM 5-3805-291-23-2
FUSE, RELAY, CIRCUIT BREAKER, AND ARC SUPPRESSOR REPLACEMENT - CONTINUED
0053 00
ARC SUPPRESSOR
N OT E
All arc suppressors are replaced in the same manner.
Removal
1.
Cut tie strap (27) and discard.
2.
Remove arc suppressor (28) from wiring harness (29).
Installation
1.
Install arc suppressor (28) on wiring harness (29).
2.
Install new tie strap (27).
483-1037
END OF WORK PACKAGE
0053 00-9/(0053 00-10 Blank)