WORKLIGHTS MAINTENANCE - CONTINUED
ATMOSPHERIC PRESSURE SENSOR REPLACEMENT

Field Maintenance Manual 2 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  138    139    140    141    142  143  144    145    146    147    148  
img
TM 5-3805-291-23-2
WORKLIGHTS MAINTENANCE - CONTINUED
0072 00
LAMP HOUSING REMOVAL
0072 00
1.
Disconnect wiring harness (10) from lamp housing
(4).
427-C0425
2.
Remove two bolts (11) and washers (12) from bracket
(13).
3.
Remove lamp housing (4) from bracket (13).
427-C0426
LAMP HOUSING INSTALLATION
1.
Install lamp housing (4) on bracket (13).
2.
Install two washers (12) and bolts (11) on bracket (13).
3.
Connect wiring harness (10) to lamp housing (4).
4.
Turn battery disconnect switch to ON position (TM 5-3805-291-10).
5.
Verify correct light operation (TM 5-3805-291-10).
END OF WORK PACKAGE