TM 5-3805-291-23-2
INTAKE MANIFOLD REPLACEMENT - CONTINUED
0185 00
REMOVAL
WARN I N G
DO NOT perform fuel system checks, inspections, or maintenance while smoking or near fire, flames,
or sparks. Fuel may ignite, causing injury or death to personnel or damage to equipment.
When servicing this machine, performing maintenance, or disposing of materials such as engine cool-
ant, hydraulic fluid, lubricants, battery acids or batteries, and CARC paint, consult your unit/local
hazardous waste disposal center or safety office for local regulatory guidance. If further information is
needed, please contact The Army Environmental Hotline at 1-800-872-3845.
DO NOT disconnect or remove any hydraulic system line or fitting unless engine is shut down and
hydraulic system pressure has been relieved. Tighten all connections before applying pressure. Escap-
ing hydraulic fluid under pressure can penetrate the skin, causing injury to personnel.
At operating temperature, hydraulic oil is hot. Allow hydraulic oil to cool before disconnecting any
hydraulic lines. Failure to follow this warning may result in injury to personnel.
1.
Remove bolt (1) and washer (2) from bracket (3).
2.
Position two hoses (4) with clamps (5) aside.
3.
Remove nut (6), washer (7), and bracket (8) from stud
(9).
4.
Disconnect two wiring harnesses (10) from sensors
(11).
427-C1030
0185 00-2