REFRIGERANT HOSES, LINES, VALVES, FLANGES, AND FITTINGS REPLACEMENT - CONTINUED
INLINE REFRIGERANT DRYER REPLACEMENT - CONTINUED

Field Maintenance Manual 2 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  1178    1179    1180    1181    1182  1183  1184    1185    1186    1187    1188  
img
. . . . . . . . . .
4
TM 5-3805-291-23-2
INLINE REFRIGERANT DRYER REPLACEMENT
0224 00
THIS WORK PACKAGE COVERS
Removal, Installation
INITIAL SETUP
Maintenance Level
Personnel Required
Direct Support
MOS 52C, Utilities Equipment Repairer
Tools and Special Tools
Equipment Conditions
Tool kit, general mechanic's, automotive (Item 90,
Hood opened (TM 5-3805-291-10)
WP 0232 00)
Shop equipment, automotive maintenance and
Steering frame lock connected (TM 5-3805-291-
repair: field maintenance, basic, less power (Item
10)
68, WP 0232 00)
Side cover removed (WP 0135 00)
Materials/Parts
AC refrigerant serviced (WP 0222 00)
Cap set, protective (Item 6, WP 0233 00)
Drawings Required
Oil, lubricating, refrigerant compressor: Synthetic
Ester (Item 30, WP 0233 00)
TM 5-3805-291-23P, Figure 175
Rag, wiping (Item 35, WP 0233 00)
Estimated Time to Complete Task
Tag, marker (Item 43, WP 0233 00)
O-ring (2)
3.0 hr
REMOVAL
WARN I N G
When servicing this machine, performing maintenance, or disposing of materials such as engine cool-
ant, hydraulic fluid, lubricants, battery acids or batteries, and CARC paint, consult your unit/local
hazardous waste disposal center or safety office for local regulatory guidance. If further information is
needed, please contact The Army Environmental Hotline at 1-800-872-3845.
Take care to prevent refrigerant from touching your skin or eyes. Liquid refrigerant, when exposed to
air, quickly evaporates and will freeze skin or eye tissue. Use protective gloves and goggles. Serious
injury or blindness may result if you come in contact with liquid refrigerant.
Refrigerant R-134a air conditioning systems should not be pressure tested or leak tested with com-
pressed air. Combustible mixtures of air and R-134a may form, resulting in a fire or explosion, which
could cause injury or death to personnel.
DO NOT work in an area where refrigerant may contact an open flame or burning material such as a
cigarette. When refrigerant contacts extreme heat, refrigerant breaks down into poisonous phosgene
gas which, if breathed, causes severe respiratory irritation. DO NOT breathe fumes from an open
flame leak detector.
0224 00-1