INLINE REFRIGERANT DRYER REPLACEMENT - CONTINUED
REFRIGERANT ACCUMULATOR REPLACEMENT

Field Maintenance Manual 2 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  1181    1182    1183    1184    1185  1186  1187    1188    1189    1190    1191  
img
. .
TM 5-3805-291-23-2
INLINE REFRIGERANT DRYER REPLACEMENT - CONTINUED
0224 00
INSTALLATION - CONTINUED
5.
Install new O-ring (2) in tube (1) and connect tube to
inline refrigerant dryer (3).
WAR N I N G
Before operating the machine, secure the steering frame lock in the stowed position. DO NOT operate
machine with steering frame lock connected. Failure to lock steering frame lock into the stowed position
before operating can result in loss of steering and injury or death to personnel.
6.
Secure steering frame lock in stowed position (TM 5-3805-291-10).
7.
Run engine until normal temperature is reached (TM 5-3805-291-10).
8.
Shut down engine (TM 5-3805-291-10).
9.
Charge AC system (WP 0222 00).
10.
Verify correct operation of AC system (TM 5-3805-291-10).
11.
Install side cover (WP 0135 00).
12.
Close hood (TM 5-3805-291-10).
END OF WORK PACKAGE