TM 5-3805-291-23-2
REFRIGERANT ACCUMULATOR REPLACEMENT - CONTINUED
0225 00
REMOVAL - CONTINUED
C AU T I O N
.
Use two line wrenches to avoid damage to fittings
Wipe area clean around all connections to be opened during removal. Cap lines and hoses and plug
openings after removing lines. Contamination of system could result in premature failure.
N OT E
Refrigerant capacity is 5.5 lb (2.4 kg).
Tag hoses prior to removal to ensure correct installation.
Use a container to catch any fluid that may drain from hoses or system. Dispose of fluid IAW local pol-
icy and ordinances. Ensure all spills are cleaned up.
Refrigerant is odorless. As a result, all of it may leak away and not be noticed until system stops cool-
ing. All vehicle refrigerant systems lose some refrigerant depending on the condition of system. Higher
loss rates signal a need to locate and repair leaks.
Leaks are most often found at the compressor hose connections and at various fittings and joints in sys-
tem. If unapproved replacement hoses are installed, refrigerant can be lost through hose permeation.
1.
Disconnect tube (1) and remove O-ring (2) from
refrigerant accumulator (3). Discard O-ring.
0225 00-2