AIR CONDITIONING SYSTEM CONDENSER REPLACEMENT - CONTINUED
AIR CONDITIONING SYSTEM CONDENSER REPLACEMENT - CONTINUED

Field Maintenance Manual 2 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  1188    1189    1190    1191    1192  1193  1194    1195    1196    1197    1198  
img
TM 5-3805-291-23-2
AIR CONDITIONING SYSTEM CONDENSER REPLACEMENT - CONTINUED
0226 00
INSTALLATION
N OT E
Apply a thin coat of clean refrigerant oil to all O-rings prior to installation.
1.
Position refrigerant condenser (3) on mounting brack-
ets (9 and 6).
2.
Install two washers (8) and bolts (7) on mounting
bracket (9).
427-C1193
3.
Install two washers (5) and bolts (4) on mounting
bracket (6).
4.
Install two new O-rings (2) in hose assemblies (1) and
connect hose assemblies to refrigerant condenser (3).
0226 00-4