ELECTRICAL TROUBLESHOOTING - EC001 HYDRAULIC CHARGE PRESSURE IS TOO LOW
ELECTRICAL TROUBLESHOOTING - EC002 ENGINE OIL PRESSURE IS TOO LOW

Field Maintenance Manual For M400T And M400W
Page Navigation
  51    52    53    54    55  56  57    58    59    60    61  
img
. . . . . . . . . . . . . . .
TM 5-3805-292-23
0006
ELECTRICAL TROUBLESHOOTING - EC001 HYDRAULIC CHARGE PRESSURE IS TOO LOW CONTINUED
N
Check for continuity between
charge pressure switch 30-A,
Continuity
Repair circuit 178 (B) or replace chassis
circuit 178AU (B), harness side,
NO
present?
wiring harness (WP 0146).
and ground (WP 0175, Frame 19.
Miscellaneous Circuits).
YES
Repair or replace brake pilot valve
Disassemble/inspect brake pilot
Damaged?
YES
valve (WP 0070).
(WP 0070).
NO
Perform Checks To Perform
Problem
Before Troubleshooting
Stop.
NO
still exists?
Hydrostatic System (WP 0007).
YES
Perform Checking DA Pressure
Problem
Stop.
NO
(WP 0007).
still exists?
YES
Perform Checking Charge
Problem
Stop.
NO
Pressure/Flow (WP 0007).
still exists?
YES
Perform Checking Circuit Relief
Pressure
Stop.
NO
Valve Pressure (WP 0007).
still low?
YES
Cap two large lines at drive
Pressure
Replace drive motor in question
motor in question and repeat
NO
circuit relief pressure check
still low?
(WP 0066, WP 067 or WP 0076).
(WP 0007).
YES
Replace tandem pump
(WP 0068 or WP 0078).
0006-28


Privacy Statement
Press Release
Contact