8
TM 5-3805-292-23
FIELD MAINTENANCE
-
TANDEM PUMP REPLACEMENT
0078
REMOVAL, CLEANING AND INSPECTION, INSTALLATION
EFFECTIVITY NOTICE
MODEL M400T
INITIAL SETUP
Tools and Special Tools
Personnel Required
0
0
Two
0
33)
0
References
0
0
TM 5-3805-292-10
Wrench, Torque, Click, Ratcheting, 1/2 in.
0
TM 5-3805-292-23P, Figures 44 and 46
Drive, 250 lb-ft (contained in SATS) (WP
0
0
0
Lifting Device, 500-lb Capacity
0
0
Materials/Parts
Equipment Conditions
0
0
0
0
Cleaning Compound, Solvent, Type III (WP
0
Backup alarm pressure switch removed
0
0
16)
Hydraulic oil temperature sender removed
0
0
0
0
Estimated Time to Complete
0
O-ring
0
6.0 Hr
0
WARN I N G
When servicing this machne, performing maintenance, or disposing of hazardous
i
materials, consult your unit/local hazardous waste disposal center or safety office for local
regulatory guidance. If further information is needed, please contact The Army
Environmental Hotline at 1-800-872-3845.
DO NOT disconnect or remove any hydraulic system lines or fitting unless engine is shut
down and hydraulic system pressure has been relieved. Tighten all connections before
applying pressure. Escaping hydraulic fluid under pressure can penetrate the skin.
At operating temperature, hydraulic oil is hot.Allow hydraulic oil to cool before removing
any hydraulic fitting.
To prevent injury to personnel, wear protective eye covering and gloves.
Failure to follow these warnings may result in injury or death to personnel.
0078-1