Figure 1. Guard, Shroud, and Fan.
FAN, PULLEY, AND SHROUD REPLACEMENT - Continued

Field Maintenance Manual For M400T And M400W
Page Navigation
  186    187    188    189    190  191  192    193    194    195    196  
img
. .
TM 5-3805-292-23
0015
REMOVAL CONTINUED
Pulley Removal
00015
1. Remove serpentine belts (WP 0052).
2. Remove pulley (Figure 2, Item 1) from engine (Figure 2, Item 2).
Figure 2. Pulley.
0015
END OF TASK
CLEANING AND INSPECTION
00015
WARN I N G
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and
low toxic material. However, it may be irritating to the eyes and skin. Use protective gloves
and goggles. Use in well-ventilated areas. Keep away from open flames and other
sources of ignition. Failure follow this warning may result in injury or death to personnel.