REMOVAL CONTINUED
2. Position throttle to full throttle (TM 5-3805-292-10).
3. Loosen bolts (Figure 2, Items 3, 4, 6 and 7) and remove serpentine belt (Figure 2, Item 2) from assembled A/C
compressor and mounting bracket (Figure 2, Item 1).
N OT E
Leave A/C compressor attached to mounting bracket.
4. Remove three bolts (Figure 2, Item 5) from machine and position assembled A/C compressor and mounting
bracket (Figure 2, Item 1) aside.
Figure 2. Assembled A/C Compressor and Mounting Bracket.
0055