Figure 3. Air Cleaner and Hoses Removal.
Figure 5. Air Cleaner Cover.

Field Maintenance Manual For M400T And M400W
Page Navigation
  423    424    425    426    427  428  429    430    431    432    433  
img
.
TM 5-3805-292-23
0058
DISASSEMBLY
00058
1. Remove four bolts (Figure 4, Item 1), washers (Figure 4, Item 2), and bracket (Figure 4, Item 4) from air
cleaner (Figure 4, Item 7).
2. Remove clamp (Figure 4, Item 15), clamp (Figure 4, Item 16), and hose (Figure 4, Item 14) from tube (Figure 4,
Item 17).
3. Remove clamp (Figure 4, Item 20), clamp (Figure 4, Item 10), and hose (Figure 4, Item 9) from tube (Figure 4,
Item 17).
4. Remove clamp (Figure 4, Item 19) and tube (Figure 4, Item 17) from hose (Figure 4, Item 21).
5. Remove clamp (Figure 4, Item 8) and hose (Figure 4, Item 21) from air cleaner (Figure 4, Item 7).
Figure 4. Air Cleaner and Hoses Disassembly.