AIR CLEANER AND HOSES MAINTENANCE
Figure 3. Air Cleaner and Hoses Removal.

Field Maintenance Manual For M400T And M400W
Page Navigation
  421    422    423    424    425  426  427    428    429    430    431  
img
.
TM 5-3805-292-23
0058
REMOVAL
00058
N OT E
Tag wiring harness to aid in installation.
1. Disconnect electrical connector (Figure 1, Item 2) from air restriction gauge (Figure 1, Item 3).
2. Remove air restriction switch (Figure 1, Item 3) from air cleaner assembly (Figure 1, Item 1).
Figure 1. Air Restriction Switch.
0058
3. Remove safety relief valve (Figure 2, Item 2) from air cleaner assembly (Figure 2, Item 1).
Figure 2. Relief Valve.
0058
0058-2