Figure 1. Air Restriction Switch.
Figure 4. Air Cleaner and Hoses Disassembly.

Field Maintenance Manual For M400T And M400W
Page Navigation
  422    423    424    425    426  427  428    429    430    431    432  
img
.
TM 5-3805-292-23
0058
REMOVAL CONTINUED
4. Loosen clamp (Figure 3, Item 15) and clamp (Figure 3, Item 20).
5. Remove nut (Figure 3, Item 11), washer (Figure 3, Item 12), bolt (Figure 3, Item 18), and tube (Figure 3, Item
17) from bracket (Figure 3, Item 13).
N OT E
Remove nuts (Figure 3, Item 3) only if damage is noted.
6. Remove three bolts (Figure 3, Item 6), washers (Figure 3, Item 5), air cleaner assembly (Figure 3, Item 7), and
three nuts (Figure 3, Item 3) from machine.
Figure 3. Air Cleaner and Hoses Removal.
0058
0058-3