Figure 3. Windshield Washer Reservoir Wiring.
Figure 5. Front Access Door Jumper Wiring.

Field Maintenance Manual For M400T And M400W
Page Navigation
  999    1000    1001    1002    1003  1004  1005    1006    1007    1008    1009  
img
.
TM 5-3805-292-23
0147
INSTALLATION
000147
N OT E
Connect all electrical connections as tagged during removal.
Secure harness with new tiedown straps.
1. Position front access door jumper electrical harness (Figure 3, Item 3) to place on machine.
2. Connect electrical connector (Figure 3, Item 2) to windshield washer reservoir (Figure 3, Item 4).
3. Connect front access door wiring jumper electrical connector (Figure 3, Item 5) to electrical connector (Figure
3, Item 6).
4. Install floor access plate (Figure 4, Item 3), three washers (Figure 4, Item 2), and bolts (Figure 4, Item 1), to
machine.
Figure 4. Floor Access Plate.
0147
0147-5