Figure 4. Floor Access Plate.
ENGINE OIL PRESSURE SENSOR REPLACEMENT

Field Maintenance Manual For M400T And M400W
Page Navigation
  1000    1001    1002    1003    1004  1005  1006    1007    1008    1009    1010  
img
. .
TM 5-3805-292-23
0147
INSTALLATION CONTINUED
5. Connect door switch electrical connector (Figure 5, Item 7) to door jumper wiring electrical connector (Figure 5,
Item 6).
6. Install two clamps (Figure 5, Item 4), and bolts (Figure 5, Item 3), to door jumper wiring harness (Figure 5, Item
5).
7. Connect door wiring electrical connector (Figure 5, Item 1) to door jumper wiring electrical connector (Figure 5,
Item 2).
8. Install suppressor (Figure 5, Item 8) on door jumper wiring harness (Figure 5, Item 5).
Figure 5. Front Access Door Jumper Wiring.
0147
END OF TASK
FOLLOW-ON TASKS
000147
1. Connect battery power (WP 0142).
2. Verify correct operation of machine (TM 5-3805-292-10).
END OF TASK
END OF WORK PACKAGE