TM 5-3805-292-23
0147
INSTALLATION CONTINUED
5. Connect door switch electrical connector (Figure 5, Item 7) to door jumper wiring electrical connector (Figure 5,
Item 6).
6. Install two clamps (Figure 5, Item 4), and bolts (Figure 5, Item 3), to door jumper wiring harness (Figure 5, Item
5).
7. Connect door wiring electrical connector (Figure 5, Item 1) to door jumper wiring electrical connector (Figure 5,
Item 2).
8. Install suppressor (Figure 5, Item 8) on door jumper wiring harness (Figure 5, Item 5).
Figure 5. Front Access Door Jumper Wiring.
0147
END OF TASK
FOLLOW-ON TASKS
000147
2. Verify correct operation of machine (TM 5-3805-292-10).
END OF TASK
END OF WORK PACKAGE