TM 5-3805-292-23
0158
REMOVAL CONTINUED
C AU T I O N
Lift console only high enough to disconnect power plug wiring harness. Failure to follow
this caution may result in damage to equipment.
N OT E
Tag wires to aid in installation.
2. Remove retainer (Figure 2, Item 2) from plug (Figure 2, Item 4).
3. Lift console and remove plug (Figure 2, Item 4) from RH console (Figure 2, Item 1).
4. Disconnect two wires (Figure 2, Item 3) from plug (Figure 2, Item 4).
Figure 2. Power Plug Outlet.
0158
END OF TASK