Figure 3. Auger Hoses and Mounting Installation.
ATTACHMENT CONTAINER REPAIR

Field Maintenance Manual For M400T And M400W
Page Navigation
  1086    1087    1088    1089    1090  1091  1092    1093    1094    1095    1096  
img
.
TM 5-3805-292-23
0167
INSTALLATION CONTINUED
Auger Drive
000167
4. Install two new O-rings (Figure 4, Item 5) and fittings (Figure 4, Item 4) on auger drive (Figure 4, Item 3).
5. Install two fittings (Figure 4, Item 2) on fittings (Figure 4, Item 4).
6. Connect two hoses (Figure 4, Item 1) on fittings (Figure 4, Item 2).
7. Remove wooden blocks from auger drive (Figure 3, Item 3).
Figure 4. Auger Drive Installation.
0167
END OF TASK
FOLLOW-ON TASKS
000167
Verify correct operation of auger (TM 5-3805-292-10).
END OF TASK
END OF WORK PACKAGE