AUGER REPAIR
Figure 2. Auger Hoses and Mounting Removal.

Field Maintenance Manual For M400T And M400W
Page Navigation
  1082    1083    1084    1085    1086  1087  1088    1089    1090    1091    1092  
img
.
TM 5-3805-292-23
0167
REMOVAL
000167
Auger Drive
000167
1. Support drive housing on blocks of wood so drive housing is horizontal.
2. Disconnect two hoses (Figure 1, Item 1) from fittings (Figure 1, Item 2).
3. Remove two fittings (Figure 1, Item 2) from fittings (Figure 1, Item 4).
4. Remove two fittings (Figure 1, Item 4) and O-rings (Figure 1, Item 5) from auger drive (Figure 1, Item 3). Dis-
card O-rings.
Figure 1. Auger Drive Removal.
0167
5. Remove two retaining pins (Figure 2, Item 9), pivot pin (Figure 2, Item 10), and auger drive (Figure 2, Item 11)
from quick attach mounting bracket (Figure 2, Item 1).
END OF TASK