TM 5-3805-298-23-1
0035
Table 1. Engine Cranks But Does Not Run - Continued.
035
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Engine Cranks But Does Not
Run - Continued
Tubes for Leaks, Sharp Bends, and
Pinched or Damaged Areas.
1. Position seal (Figure 9, Item 4) on
machine, and install two spacers
(Figure 9, Item 3), washers
(Figure 9, Item 2), and bolts
(Figure 9, Item 1) on machine.
Figure 9. Seal.
0035
2. Remove right engine access panel
(WP 0348).
3. With an assistant, activate the
electric fuel priming pump switch
(TM 5-3805-298-10).
4. Inspect fuel tube (Figure 10,
Fuel Tube OK - Proceed to step 5.
Item 1) between cylinder head
Fuel Tube Leaks - Tighten or replace
(Figure 10, Item 2) and fuel
fuel tube (WP 0210).
injection pump (Figure 10, Item 3)
Proceed to Test Step 12.
for Class I, II, or III leaks.
5. Inspect fuel tube (Figure 10,
Fuel Tube OK - Proceed to step 6.
Item 1) between cylinder head
Fuel Tube Pinched, Damaged, or Has
(Figure 10, Item 2) and fuel
Sharp Bends - Replace fuel tube
injection pump (Figure 10, Item 3)
(WP 0210).
for sharp bends and pinched or
Proceed to Test Step 12.
damaged areas.