TM 5-3805-298-23-1
0036
Table 1. Engine Does Not Crank or Cranks Slowly - Continued.
036
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Engine Does Not Crank or
NOTE
Cranks Slowly - Continued
Battery type and rating are located on battery label.
4. Perform battery test (WP 0165) on
Battery Analyzer Displays GOOD
each battery using battery
BATTERY - Proceed to step 5.
analyzer.
Battery Analyzer Displays GOOD
RECHARGE - Charge affected battery
(WP 0165).
If removed, install batteries in machine
(WP 0281).
Proceed to Test Step 10.
Battery Analyzer Displays CHARGE
& RETEST - Charge and test affected
battery (WP 0165):
a. If battery analyzer displays
CHARGE & RETEST again,
replace affected battery
(WP 0281). Proceed to Test
Step 10
b. If battery analyzer displays OK,
install batteries in machine
(WP 0281). Proceed to Test
Step 10.
Battery Analyzer Displays REPLACE
BATTERY - Replace affected battery
(WP 0281).
Proceed to Test Step 10.
5. Remove left engine access panel
(WP 0350).
6. Inspect starter motor for loose,
Starter Motor and Bolts Clean and
Tight - Proceed to step 7.
damaged, corroded, bent, or
missing bolts.
Starter Motor Bolts Loose, Corroded,
Bent, or Missing - Tighten or install
new starter motor bolts (WP 0240).
Install left engine access panel
(WP 0350).
Proceed to Test Step 10.
0036-5