TM 5-3805-298-23-1
0086
Table 1. 271 Action Alarm Diagnostic Codes - Continued.
086
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
NOTE
271-6 Action Alarm Current
Above Normal
Always inspect wiring harness connectors that are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure and
that all connections are in good condition. If a problem with the
connection is found, correct the problem and verify that this malfunction
or diagnostic code is active before performing this procedure.
Perform open or short-circuit test at each wiring harness connection to
identify the correct wiring harness to replace.
Tag all wiring harnesses to aid in installation.
Perform this test only if condition is active.
DIAGNOSTIC CODE SET CONDITION
Transmission ECM detects a short circuit or high current condition in the action
alarm circuit.
POSSIBLE CAUSE
Lower cab wiring harness shorted.
Action alarm circuit faulty.
Test Step 1. Check for Active
Diagnostic Codes.
Connect MSD, select Transmission
Diagnostic Code 271-6 Active -
924H, and check for active diagnostic
Proceed to Test Step 2.
Diagnostic Code 271-6 Not Active -
Troubleshooting is complete.