Table 1. 291 Demand Fan Solenoid Diagnostic Codes - Continued.
087
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
5. Disconnect connector M-C1
291-3 Demand Fan Solenoid
Voltage Is Above Normal -
Continued
Figure 56).
(WP 0174), test for continuity
harness (WP 0295).
between connector M-C1
Proceed to Test Step 4.
No Continuity - Proceed to Test Step 3.
and all other M-C1 terminals.
Test Step 3. Test for Shorted Lower
Cab Wiring Harness.
1. Remove left lower cab access
panels (WP 0347).
2. Remove transmission ECM cover
(WP 0266).
3. Disconnect connector C-C12
Transmission ECM J1.
(WP 0174), test for continuity
harness (WP 0291).
between connector C-C12
Proceed to Test Step 4.
No Continuity - Replace transmission
and all other C-C12 terminals.
ECM (WP 0266).
Proceed to Test Step 4.
Test Step 4. Verify Malfunction Is
Resolved.
1. Ensure all harness connectors are
connected.
2. Install fan (WP 0234).
3. Install transmission ECM cover
(WP 0266).
4. Install right and left lower cab
access panels (WP 0347).
5. Using MSD, check for active
Diagnostic Code 291-3 Demand Fan
Becomes Inactive - Troubleshooting
complete.
Diagnostic Code 291-3 Demand Fan
Remains Active - Repeat
troubleshooting from the beginning.
0087-3