Table 1. 444 Start Relay Diagnostic Codes - Continued.
473 BRAKE CHARGING OIL PRESSURE SENSOR DIAGNOSTIC CODES

Field Maintenance Manual For 924H Wheel Loader -1 Page Navigation
  992    993    994    995    996  997  998    999    1000    1001    1002  
img
. . . .
TM 5-3805-298-23-1
0092
Table 1. 444 Start Relay Diagnostic Codes - Continued.
092
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
444-6 Start Relay Current
Test Step 4. Test for Shorted Lower
Above Normal - Continued
Cab Wiring Harness.
1. Remove left lower cab access
panels (WP 0347).
2. Remove transmission ECM cover
(WP 0266).
3. Disconnect connector C-C13
(WP 0012, Figure 25) from
Transmission ECM J2.
4. Using digital multimeter
Continuity - Replace lower cab wiring
(WP 0174), test for continuity
harness (WP 0291).
between connector C-C13
Proceed to Test Step 5.
(WP 0012, Figure 25) terminal 7
No Continuity - Proceed to step 5.
and terminal 8.
5. Using digital multimeter
Continuity - Replace lower cab wiring
(WP 0174), test for continuity
harness (WP 0291).
between connector C-C13
Proceed to Test Step 5.
(WP 0012, Figure 25) terminal 7
No Continuity - Replace transmission
and ground.
ECM (WP 0266).
Proceed to Test Step 5.
Test Step 5. Verify Malfunction Is
Resolved.
1. Ensure all wiring harness
connectors are connected.
2. Install left engine access panel
(WP 0350).
3. Install transmission ECM cover
(WP 0266).
4. Install right and left lower cab
access panels (WP 0347).
5. Start engine (TM 5-3805-298-10).
6. Using MSD, check for active
Diagnostic Code 444-6 Start Relay
diagnostic codes (WP 0008).
Current Above Normal Becomes
Inactive - Troubleshooting complete.
Diagnostic Code 444-6 Start Relay
Current Above Normal Remains
Active - Repeat troubleshooting from
the beginning.
END OF WORK PACKAGE
0092-9/(10 blank)