Table 1. 1405 Solenoid Valve 5 (Third Gear) Diagnostic Codes - Continued.
Table 1. 1405 Solenoid Valve 5 (Third Gear) Diagnostic Codes - Continued.

Field Maintenance Manual For 924H Wheel Loader -1 Page Navigation
  1172    1173    1174    1175    1176  1177  1178    1179    1180    1181    1182  
img
. . . . . . .
TM 5-3805-298-23-1
0114
Table 1. 1405 Solenoid Valve 5 (Third Gear) Diagnostic Codes - Continued.
0114
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
6. Turn transmission control lever to
1405-6 Solenoid Valve 5
3 and push to F (forward) position
(Third Gear) Current Above
(TM 5-3805-298-10).
Normal - Continued
7. Using MSD, check for active
Diagnostic Code 1405-5 Solenoid
diagnostic codes (WP 0008).
Valve 5 (Third Gear) Current Below
Normal Becomes Active Replace
clutch solenoid valve 5 (third gear)
(WP 0310).
Proceed to Test Step 5.
Diagnostic Code 1405-6 Solenoid
Valve 5 (Third Gear) Current Above
Normal Remains Active Proceed to
Test Step 3.
Test Step 3. Test for Shorted
Transmission Wiring Harness.
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-298-10).
2. Disconnect connector P-C1
(WP 0012, Figure 53) from
connector C-C15 (WP 0012,
Figure 52).
3. Using digital multimeter
Continuity Replace transmission
(WP 0174), test for continuity
wiring harness (WP 0298).
between connector P-C1
Proceed to Test Step 5.
(WP 0012, Figure 53) terminal 12
No Continuity Proceed to step 4.
and terminal 15.
4. Using digital multimeter
Continuity Replace transmission
(WP 0174), test for continuity
wiring harness (WP 0298).
between connector P-C1
Proceed to Test Step 5.
(WP 0012, Figure 53) terminal 15
No Continuity Proceed to Test
and ground.
Step 4.
Test Step 4. Test for Shorted Lower
Cab Wiring Harness.
1. Remove left lower cab access
panels (WP 0347).
2. Remove transmission ECM cover
(WP 0266).
3. Disconnect connector C-C12
(WP 0012, Figure 26) from
Transmission ECM J1.
4. Using digital multimeter
Continuity Replace lower cab wiring
(WP 0174), test for continuity
harness (WP 0291).
between connector C-C12
Proceed to Test Step 5.
(WP 0012, Figure 26) terminal 50
No Continuity Proceed to step 5.
and terminal 51.
0114-8