Table 1. Dome Light Does Not Operate - Continued.
Table 1. Dome Light Does Not Operate - Continued.

Field Maintenance Manual For 924H Wheel Loader -1 Page Navigation
  1252    1253    1254    1255    1256  1257  1258    1259    1260    1261    1262  
img
. . . . .
TM 5-3805-298-23-1
0122
Table 1. Dome Light Does Not Operate - Continued.
0122
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
5. Remove blackout turn/flash relay
Dome Light Does Not
(TM 5-3805-298-10) from fuse
Operate - Continued
panel.
6. Using digital multimeter
Resistance 288 Ohms to 414 Ohms
(WP 0174), measure resistance
Proceed to step 7.
between blackout turn/flash relay
Resistance Less Than 288 Ohms
(WP 0012, Figure 154) terminal 85
Replace blackout turn/flash relay
and terminal 86.
(TM 5-3805-298-10).
Proceed to Test Step 23.
7. Remove blackout brake light relay
(TM 5-3805-298-10) from fuse
panel.
8. Using digital multimeter
Resistance 288 Ohms to 414 Ohms
(WP 0174), measure resistance
Proceed to step 9.
between blackout brake light relay
Resistance Less Than 288 Ohms
(WP 0012, Figure 154) terminal 85
Replace blackout brake light relay
and terminal 86.
(TM 5-3805-298-10).
Proceed to Test Step 23.
9. Remove blackout backup alarm
relay (TM 5-3805-298-10) from
fuse panel.
10. Using digital multimeter
Resistance 288 Ohms to 414 Ohms
(WP 0174), measure resistance
Proceed to step 11.
between blackout backup alarm
Resistance Less Than 288 Ohms
relay (WP 0012, Figure 154)
Replace blackout backup alarm relay
terminal 85 and terminal 86.
(TM 5-3805-298-10).
Proceed to Test Step 23.
11. Remove blackout flood light relay
(TM 5-3805-298-10) from fuse
panel.
12. Using digital multimeter
Resistance 288 Ohms to 414 Ohms
(WP 0174), measure resistance
Proceed to Test Step 19.
between blackout flood light relay
Resistance Less Than 288 Ohms
(WP 0012, Figure 154) terminal 85
Replace blackout flood light relay
and terminal 86.
(TM 5-3805-298-10).
Proceed to Test Step 23.
Test Step 19. Test for Shorted Wiring
Harness.
1. Turn the military light switch to
OFF position (TM 5-3805-298-10).
2. Using digital multimeter
Continuity Proceed to Test Step 20.
(WP 0174), test for continuity
No Continuity Proceed to Test
between connector C-C31
Step 21.
(WP 0012, Figure 74) terminal D1
and terminal D2.
0122-9