Table 1. One or Both Front Work Lights Do Not Operate - Continued.
Table 1. One or Both Front Work Lights Do Not Operate - Continued.

Field Maintenance Manual For 924H Wheel Loader -2 Page Navigation
  34    35    36    37    38  39  40    41    42    43    44  
img
. . . . .
TM 5-3805-298-23-2
0134
Table 1. One or Both Front Work Lights Do Not Operate - Continued.
0134
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3. Remove blackout headlight relay
One or Both Front Work
(TM 5-3805-298-10) from fuse
Lights Do Not Operate -
panel.
Continued
4. Using digital multimeter
Resistance 288 Ohms to 414 Ohms
(WP 0174), measure resistance
Proceed to step 5.
between blackout headlight relay
Resistance Less Than 288 Ohms
(WP 0012, Figure 154) terminal 86
Replace blackout headlight relay
and terminal 85.
(TM 5-3805-298-10).
Proceed to Test Step 31.
5. Remove blackout turn/flash relay
(TM 5-3805-298-10) from fuse
panel.
6. Using digital multimeter
Resistance 288 Ohms to 414 Ohms
(WP 0174), measure resistance
Proceed to step 7.
between blackout turn/flash relay
Resistance Less Than 288 Ohms
(WP 0012, Figure 154) terminal 86
Replace blackout turn/flash relay
and terminal 85.
(TM 5-3805-298-10).
Proceed to Test Step 31.
7. Remove blackout brake light relay
(TM 5-3805-298-10) from fuse
panel.
8. Using digital multimeter
Resistance 288 Ohms to 414 Ohms
(WP 0174), measure resistance
Proceed to step 9.
between blackout brake light relay
Resistance Less Than 288 Ohms
(WP 0012, Figure 154) terminal 86
Replace blackout brake light relay
and terminal 85.
(TM 5-3805-298-10).
Proceed to Test Step 31.
9. Remove blackout backup alarm
relay (TM 5-3805-298-10) from
fuse panel.
10. Using digital multimeter
Resistance 288 Ohms to 414 Ohms
(WP 0174), measure resistance
Proceed to step 11.
between blackout backup alarm
Resistance Less Than 288 Ohms
relay (WP 0012, Figure 154)
Replace blackout backup alarm relay
terminal 86 and terminal 85.
(TM 5-3805-298-10).
Proceed to Test Step 31.
11. Remove blackout flood light relay
(TM 5-3805-298-10) from fuse
panel.
12. Using digital multimeter
Resistance 288 Ohms to 414 Ohms
(WP 0174), measure resistance
Proceed to Test Step 29.
between blackout flood light relay
Resistance Less Than 288 Ohms
(WP 0012, Figure 154) terminal 86
Replace blackout flood light relay
and terminal 85.
(TM 5-3805-298-10).
Proceed to Test Step 31.
0134-13