TM 5-3805-298-23-2
0166
STEERING PISTON PUMP MARGIN PRESSURE TEST CONTINUED
16. Position 5,800 psi (40,000 kPa) gauge (Figure 6, Item 1) and 3,600 psi (25,000 kPa) gauge (Figure 7, Item 1)
so they can be easily read.
17. Turn battery disconnect switch to ON position and start engine (TM 5-3805-298-10).
18. Run engine at low idle (TM 5-3805-298-10).
19. Check fittings installed for leaks and tighten fittings as required.
20. Run engine at high idle (2,450 rpm) (TM 5-3805-298-10).
Figure 6. 5,800 psi (40,000 kPa) Gauge Assembly.
0166