Figure 1. Single Press Tab Connector.
Figure 3. Connector With Locking Clip.

Field Maintenance Manual For 924H Wheel Loader -2 Page Navigation
  452    453    454    455    456  457  458    459    460    461    462  
img
.
TM 5-3805-298-23-2
0174
DISCONNECTING AND CONNECTING WIRING HARNESS CONNECTORS CONTINUED
000174
Double Press Tab Connector (12-Pin)
000174
1. To disconnect connector, press and hold two tabs (Figure 2, Item 1) while pulling connector body.
2. To connect connector, align keyways (Figure 2, Item 2), push connector ends together until tabs (Figure 2, Item
1) click and connector body cannot be pulled apart.
Figure 2. Double Press Tab Connector (12-Pin).
0174
0174-3