NOTE
Remove caps or plugs from elbow fittings and install as noted during removal.
Use container to catch any fluid that may drain from system. Dispose of fluid IAW local
policy and ordinances. Ensure all spills are cleaned up.
9. Install two new O-rings (Figure 12, Item 5) and elbow fitting (Figure 12, Item 6) on third fuel filter base
(Figure 12, Item 7).
10. Install new O-ring (Figure 12, Item 1) and adapter (Figure 12, Item 2) on third fuel filter base
(Figure 12, Item 7).
11. Install two new O-rings (Figure 12, Item 4) and elbow fitting (Figure 12, Item 3) on adapter (Figure 12, Item 2).
Figure 12. Third Fuel Filter Base Elbow Adapters and Adapter.
0223