TM 5-3805-298-23-2
0224
ETHER LINE REMOVAL
000224
WARNING
Ether fuel is extremely flammable and toxic. DO NOT smoke, and make sure you are in a
well-ventilated area away from heat, open flames or sparks. Wear eye protection. Avoid
contact with skin and eyes and avoid breathing ether fumes. If fluid enters or fumes irritate
the eyes, wash immediately with large quantities of clean water for 15 minutes. Seek
medical attention immediately if ether is inhaled or causes eye irritation. Failure to follow
this warning may cause serious injury or death to personnel.
1. Loosen two tube nuts (Figure 2, Item 2) from ether valve (Figure 2, Item 1) and fitting (Figure 2, Item 4).
2. Remove ether line (Figure 2, Item 3) from machine.
Figure 2. Ether Line.
0224