TM 5-3805-298-23-4
0384
INSTALLATION CONTINUED
NOTE
Remove caps or plugs and install hose as noted during removal.
Use container to catch any fluid that may drain from hydraulic system. Dispose of fluid IAW
local policy and ordinances. Ensure all spills are cleaned up.
7. Position drain pan to catch fluid that drains from hose (Figure 12, Item 1) or cylinder (Figure 12, Item 6).
8. Install two split flange clamps (Figure 12, Item 4), new O-ring (Figure 12, Item 5), hose (Figure 12, Item 1), four
washers (Figure 12, Item 3), and bolts (Figure 12, Item 2) on bucket lift cylinder (Figure 12, Item 6).
Figure 12. Hose, Split Flange Clamps, and O-ring.
0384