LEAK TEST
EVACUATION

Field Maintenance Manual For 924H Wheel Loader -4 Page Navigation
  444    445    446    447    448  449  450    451    452    453    454  
img
.
TM 5-3805-298-23-4
0405
RECOVERY
000405
NOTE
If service is required on A/C system, refrigerant must be recovered before A/C system
components are removed.
1. Install blue low-side hose (Figure 1, Item 4) on suction (low) side (Figure 1, Item 1) of A/C compressor 
(Figure 1, Item 3).
2. Install red high-side hose (Figure 1, Item 5) on discharge (high) side (Figure 1, Item 2) of A/C compressor
(Figure 1, Item 3).
3. Follow recovery station OEM instructions and recover R-134a refrigerant.
Figure 1. Recovery Hook-Up.
0405
END OF TASK
0405-3