CHARGING
A/C SYSTEM PERFORMANCE TEST

Field Maintenance Manual For 924H Wheel Loader -4 Page Navigation
  449    450    451    452    453  454  455    456    457    458    459  
img
.
TM 5-3805-298-23-4
0405
CHARGING CONTINUED
000405
1. Install blue low-side hose (Figure 3, Item 4) on suction (low) side (Figure 3, Item 1) of A/C compressor 
(Figure 3, Item 3).
2. Install red high-side hose (Figure 3, Item 5) on discharge (high) side (Figure 3, Item 2) of A/C compressor
(Figure 3, Item 3).
CAUTION
DO NOT invert R-134a refrigerant tank while charging A/C system. Liquid refrigerant
entering low side of A/C system will permanently damage compressor.
3. Follow recovery station OEM instructions and charge A/C system with R-134a refrigerant. Refrigerant capacity
is 6.0 lb (2.7 kg).
4. Once charging is complete, disconnect blue low-side hose (Figure 3, Item 4) from suction (low) side 
(Figure 3, Item 1) of A/C compressor (Figure 3, Item 3) and red high-side hose (Figure 3, Item 5) from
discharge (high) side (Figure 3, Item 2) of A/C compressor (Figure 3, Item 3).
5. Perform the A/C System Performance Test in this work package to verify correct operation of machine.
Figure 3. Charging Hook-Up.