TM 5-3805-298-23-4
0412
REFRIGERANT CONDENSER OUTLET HOSE REMOVAL CONTINUED
NOTE
Note routing of hose to aid installation.
Tag and mark hose to aid installation.
Cap or plug hose end and open port to protect against contamination.
4. Loosen tube nut (Figure 7, Item 2) and remove refrigerant condenser outlet hose (Figure 7, Item 1) and O-ring
(Figure 7, Item 3) from refrigerant condenser (Figure 7, Item 4). Discard O-ring.
Figure 7. Refrigerant Condenser Outlet Hose.
0412