TM 5-3805-298-23-4
0412
REFRIGERANT CONDENSER OUTLET HOSE REMOVAL CONTINUED
000412
NOTE
Note routing of hose to aid installation.
Note orientation of P-clamp to aid installation.
Note location and number of dual tiedown straps to aid installation.
5. Remove five bolts (Figure 8, Item 2), washers (Figure 8, Item 1), P-clamp (Figure 8, Item 3), and two dual
tiedown straps (Figure 8, Item 4) from refrigerant condenser outlet hose (Figure 8, Item 5). Discard dual
tiedown straps.
Figure 8. Clips and Dual Tiedown Straps.
0412