TM 5-3805-298-23-4
0412
REFRIGERANT CONDENSER OUTLET HOSE REMOVAL CONTINUED
000412
NOTE
Note routing of hose to aid installation.
Note quantity and position of tiedown straps to aid installation.
Tag and mark hose to aid installation.
Cap or plug hose end and open port to protect against contamination.
11. Remove tiedown strap (Figure 13, Item 5) from refrigerant condenser outlet hose (Figure 13, Item 1). Discard
tiedown strap.
12. Loosen tube nut (Figure 13, Item 2) and remove refrigerant condenser outlet hose (Figure 13, Item 1) and
O-ring (Figure 13, Item 3) from auxiliary refrigerant condenser (Figure 13, Item 4). Discard O-ring.
13. Remove refrigerant condenser outlet hose (Figure 13, Item 1) from machine.
Figure 13. Refrigerant Condenser Outlet Hose.
0412
END OF TASK