Figure 21. Panel.
Figure 24. Refrigerant Condenser Outlet Hose.

Field Maintenance Manual For 924H Wheel Loader -4 Page Navigation
  533    534    535    536    537  538  539    540    541    542    543  
img
.
TM 5-3805-298-23-4
0412
REFRIGERANT DRYER INLET HOSE INSTALLATION CONTINUED
000412
NOTE
Remove caps or plugs and install hose as noted during removal.
Install tiedown straps as noted during removal.
6. Install new O-ring (Figure 23, Item 2), refrigerant dryer inlet hose (Figure 23, Item 5), and tube nut
(Figure 23, Item 3) on auxiliary refrigerant condenser (Figure 23, Item 1).
7. Install new tiedown straps (Figure 23, Item 6) on auxiliary air conditioning condenser fan wiring harness
(Figure 23, Item 4) and refrigerant dryer inlet hose (Figure 23, Item 5).
8. Install air cleaner housing and bracket (WP 0204).
Figure 23. Refrigerant Dryer Inlet Hose.
0412
END OF TASK
0412-21