TM 5-3805-298-23-4
0412
REFRIGERANT DRYER INLET HOSE REMOVAL CONTINUED
000412
NOTE
Note routing of hose to aid installation.
Tag and mark hose to aid installation.
Cap or plug hose end and open port to protect against contamination.
7. Loosen tube nut (Figure 18, Item 2) and remove refrigerant dryer inlet hose (Figure 18, Item 3) and O-ring
(Figure 18, Item 1) from refrigerant dryer (Figure 18, Item 4). Discard O-ring.
8. Remove refrigerant dryer inlet hose (Figure 18, Item 3) from machine.
Figure 18. Refrigerant Dryer Inlet Hose.
0412
END OF TASK
CLEANING AND INSPECTION
000412
Clean and inspect all components IAW Mechanical General Maintenance Instructions (WP 0172).
END OF TASK