Figure 23. Refrigerant Dryer Inlet Hose.
Figure 25. Refrigerant Condenser Outlet Hose Clips.

Field Maintenance Manual For 924H Wheel Loader -4 Page Navigation
  534    535    536    537    538  539  540    541    542    543    544  
img
.
TM 5-3805-298-23-4
0412
REFRIGERANT CONDENSER OUTLET HOSE INSTALLATION
000412
NOTE
Remove caps or plugs and install hose as noted during removal.
Install tiedown straps as noted during removal.
1. Position refrigerant condenser outlet hose (Figure 24, Item 1) on machine.
2. Install new O-ring (Figure 24, Item 3), refrigerant condenser outlet hose (Figure 24, Item 1), and tube nut
(Figure 24, Item 2) on auxiliary refrigerant condenser (Figure 24, Item 4).
3. Install new tiedown strap (Figure 24, Item 5) on refrigerant condenser outlet hose (Figure 24, Item 1).
Figure 24. Refrigerant Condenser Outlet Hose.
0412
0412-22