Figure 9. Heater Grid Fuse.
Figure 11. Grid Heater Coolant Temperature Sensor.

Tractor, Wheeled, Industrial Backhoe Loader Nsn 2420-01-532-3399
Page Navigation
  216    217    218    219    220  221  222    223    224    225    226  
img
.
TM 5-2420-231-23-1
0011
Table 1. Hard Start in Cold Temperatures (50F or Below) - Continued.
011
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3. Visually inspect heater grid cable
Heater Grid Cable OK - Replace
Hard Start in Cold
(Figure 10, Item 2) between heater
heater grid assembly (WP 0114) and
Temperatures (50F or
grid relay (Figure 10, Item 1) and
heater grid fuse (WP 0160).
Below) - Continued
heater grid (Figure 10, Item 3) for
Proceed to Test Step 9.
chafing and shorting to machine.
Heater Grid Cable Chafed or Shorted
- Replace heater grid cable and heater
grid fuse (WP 0160).
Proceed to Test Step 9.
Figure 10. Heater Grid Voltage Supply Cable.