TM 5-2420-231-23-1
0038
Table 1. Rear Work Lights Do Not Function Correctly - Continued.
038
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 20. Check Rear Work
Rear Work Lights Do Not
Lights Wiring Harness for a Short.
Function Correctly -
Continued
1. Remove right rear floor cover plate
(WP 0306).
2. Disconnect rear work light wiring
from main chassis wiring harness
Continuity - Replace main chassis
continuity between rear main chas-
wiring harness (WP 0154).
sis wiring harness connector (WP
Install new rear work lights fuse (TM 5-
0007, Figure 25) terminal 6A and
2420-231-10).
machine ground. There should be
Proceed to Test Step 23.
no continuity.
wiring harness (WP 0184).
Install new rear work lights fuse (TM 5-
2420-231-10).
Proceed to Test Step 23.
Test Step 21. Check for Shorted Main
Chassis Wiring Harness.
1. Remove front instrument panel
right-side cover (WP 0176).
2. Disconnect front console wiring
ure 5) from main chassis wiring
ure 6).
Continuity - Proceed to Test Step 22.
continuity between front main
chassis wiring harness connector
wiring harness (WP 0162).
Proceed to Test Step 22.
and machine ground. There should
be no continuity.
Test Step 22. Check for Shorted Side
Console Wiring Harness.
1. Remove front instrument panel
right-side cover (WP 0176).
2. Disconnect rear main chassis wir-
Figure 25) from side console wir-
Figure 24).
Continuity - Replace side console
continuity between side console
wiring harness (WP 0170).
wiring harness connector (WP
Proceed to Test Step 23.
0007, Figure 24) terminal 3A and
machine ground. There should be
wiring harness (WP 0154).
no continuity.
Proceed to Test Step 23.