TM 5-2420-231-23-2
0092
ASSEMBLY CONTINUED
35. Connect coolant return hose (Figure 39, Item 2) and install clamp (Figure 39, Item 3) on radiator
(Figure 39, Item 1).
WARNING
Use caution when using adhesives and sealants. Prolonged inhalation of vapors can
cause lung irritation. Contact with skin can cause dermatitis. Wear gloves and safety
goggles and use product in a well-ventilated area away from open flame. If ingested, keep
individual calm and seek medical attention. DO NOT induce vomiting. If contact with skin
or eyes is made, flush thoroughly with water. Dispose of cleanup rags IAW local policy and
ordinances. Failure to follow this warning may cause injury to personnel.
36. Apply sealant to two bolts (Figure 39, Item 5).
37. Install two washers (Figure 39, Item 4) and bolts (Figure 39, Item 5) on radiator (Figure 39, Item 1).
Figure 39. Coolant Return Hose.
0092