TM 5-2420-231-23-2
0129
REMOVAL CONTINUED
NOTE
Note orientation of heater shutoff valve to aid in assembly.
4. Remove heater shutoff valve (Figure 2, Item 2) from water inlet housing (Figure 2, Item 1).
Figure 2. Heater Shutoff Valve.
0129
END OF TASK
CLEANING AND INSPECTION
0129
Clean and inspect all parts IAW Mechanical General Maintenance Instructions (WP 0369).
END OF TASK
INSTALLATION
0129
NOTE
Install heater shutoff valve as noted during removal.
1. Wrap threads of heater shutoff valve (Figure 2, Item 2) with anti-seizing teflon tape and install on water inlet
housing (Figure 2, Item 1).