NATO SLAVE CABLES REPLACEMENT
Figure 4. NATO Slave Receptacle.

Tractor, Wheeled, Industrial Backhoe Loader Nsn 2420-01-532-3399
Page Navigation
  748    749    750    751    752  753  754    755    756    757    758  
img
.
TM 5-2420-231-23-2
0198
REMOVAL CONTINUED
3. Remove two bolts (Figure 2, Item 1) and washers (Figure 2, Item 2) from equalizer cover (Figure 2, Item 3).
4. Remove bolt (Figure 2, Item 5), washer (Figure 2, Item 4), and equalizer cover (Figure 2, Item 3) from machine.
Figure 2. Equalizer Cover.
0198
NOTE
Tag and mark wires to aid in installation.
5. Position rubber boot (Figure 3, Item 5) aside.
6. Remove nut (Figure 3, Item 3) and disconnect four 24-V cables (Figure 3, Items 6, 2, 7, and 1) from junction
block (Figure 3, Item 4).
7. Remove nut (Figure 3, Item 9) and disconnect three ground cables (Figure 3, Items 8, 11, and 12) from stud
(Figure 3, Item 10).
Figure 3. 24-V Cables.
0198
0198-2