TM 5-3805-255-14
0016
Table 2. Electrical Troubleshooting Procedures for the H100C Loader - Continued.
016
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Check for loose, dirty, or defective
Clean and tighten connections or
8. Starter Motor Will Not
battery cables or terminals.
Operate or Operates
still exists, go to step 2.
Slowly.
2. Check for faulty batteries.
lem still exists, go to step 3.
3. Check for defective starting switch
Repair or replace switch. If problem
still exists, go to step 4.
4. Check for defective starter motor.
problem still exists, notify Sustainment
Maintenance.