TM 5-3805-255-14
0016
Table 4. Transmission Troubleshooting Procedures for the H100C Loader - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Check for improper loader
Operate in proper range for load and
3. Loss of Power.
operation.
exists, go to step 2.
2. Check for dragging parking brake. Adjust linkage to allow full release
to step 3.
3. Check for foaming oil.
b. Check for air leak in suction
line.
c. If oil used is not meeting spec-
ifications or if problem still
exists, go to step 4.
4. Check for dragging loader brakes. Check brake linkages. If problem still
exists, go to step 5.
5. Check for out-of-adjustment
Adjust linkage. If problem still exists,
linkage.
notify Sustainment Maintenance.