TM 5-3805-255-14
0016
Table 10. Steering Gear Troubleshooting Procedures for the H100C Loader.
016
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Check for loose gear mounting.
1. Gear Noise (Rattle or
problem still exists, notify Sustainment
Chuckle).
Maintenance.
1. Check for lack of lubrication in
2. Hard Steering.
linkage.
problem still exists, go to step 2.
2. Check for tires not properly
inflated.
problem still exists, notify Sustainment
Maintenance.
Table 11. Hydraulic General Troubleshooting Procedures for the H100C Loader.
016
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Check for defective main
Clean or replace main hydraulic pump
1. Poor Hydraulic System
hydraulic pump.
Performance or Failure.
to step 2.
2. Check for defective reservoir
Clean or replace reservoir relief valve
relief valve.
to step 3.
3. Check for worn cylinders.
go to step 4.
4. Check main control valve linkage. Adjust linkage (WP 0078). If problem
still exists, go to step 5.
5. Check reservoir level.
Add correct amount and type of fluid
to step 6.
6. Check for clogged system filter
screen.
problem still exists, go to step 7.
7. Check for restrictions in lines.
Clean, repair, or replace lines.
Check hydraulic fluid level.
Add correct amount and type of fluid
2. Excessive Oil Foaming.
notify Sustainment Maintenance.