• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 1. Field PMCS for the H100C Loader - Continued
Table 1. Field PMCS for the H100C Loader - Continued

Maintenance Manual For Loader, Scoop Type, Ded 4 X 4, Articulated Frame Steer, 4.5 To 5 Cu. Yd.
Page Navigation
  241    242    243    244    245  246  247    248    249    250    251  
img
TM 5-3805-255-14
0018
Table 1. Field PMCS for the H100C Loader - (Continued).
LOCATION
ITEM TO
CHECK/
NOT FULLY MISSION
SERVICE
CAPABLE IF:
ITEM NO. INTERVAL
PROCEDURE
Semiannually Hydraulic
31
WARNING
Reservoir Oil
(Cont.)
Draining
Solvent cleaning compound MIL-PRF-680 Type III is an envi-
ronmentally compliant and low-toxicity material. However, it
may be irritating to the eyes and skin. Use protective gloves
and goggles. Use in well-ventilated areas. Keep away from
open flames and other sources of ignition.
When servicing this equipment, performing maintenance, or
disposing of materials such as engine/hydraulic oils, coolant,
and fuel, consult your unit/local hazardous waste disposal cen-
ter or safety office for local regulatory guidance.
Engine/hydraulic oils, coolant, and fuel can be very slippery.
Immediately wipe up any spills.
Failure to follow these warnings may result in injury or death to
personnel.
e. Clean top of reservoir with cleaning
solvent.
WARNING
Always loosen filler cap slowly to relieve pressure build-up in
system. Failure to comply may cause injury to personnel and
damage to equipment.
f. Slowly loosen and remove
reservoir filler cap.
g. Remove pipe plug in drain valve.
h. Fit a short 3/4 in. (19 mm) threaded
pipe into end of a piece of hose. Screw
pipe into drain valve. Put other end of
hose into a container large enough to
hold all of fluid from reservoir.
0018-46


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.